微波EDA網(wǎng)-關(guān)于我們 微波EDA網(wǎng)-出版的圖書專著 微波EDA網(wǎng)培訓(xùn)課程列表 射頻工程師養(yǎng)成培訓(xùn)學(xué)習(xí)教程
  • 1
  • 2
  • 3
  • 4

Incident Power

Incident power for an antenna structure is defined in terms of accepted power under special conditions. In HFSS the incident power flow on a transmission structure is defined as the accepted power when that structure is terminated in a conjugate-matched load. Thus we write a general definition:

 

 

(1)

For a transmission structure that may be modeled with a real characteristic impedance, this definition is equivalent to the zero-reflective case where the transmission structure is terminated in a matched load. For example, in the simple example discussed in this section on accepted power, setting S11 = 0 produced the incident power as:

 

 

(2)

However, there is an important difference in the case of Lumped ports with complex impedance, and Wave ports renormalized to complex impedance. In these cases, the conjugate-match and zero-reflection definitions of incident power give different results, but only the conjugate-match definition used by HFSS enforces the important property that Pacc<Pinc.

In the Edit Sources window of a terminal project, you specify total voltage V instead of the modal incident power. Using the underlying modal S-matrix, HFSS converts the terminal excitation to total fields at the ports, and then applies the general definition. As a result of this procedure, the incident power in a terminal project depends on both the user-specified stimulation as well as the model itself.

Related Topics

Computing Antenna Parameters