CST中6個error的解決方案
學(xué)習(xí)CST中遇到了很多ERROR不知道怎么個意思,虛心向高人學(xué)習(xí)下。
1. The port mode Eigensolver(本征求解器) failed because the maximum number of iterations has been reached.
2. Single-ended definition requires a separate mode set for each pin .Please check waveguide Port Number.
3. The propagation constant of mode1 is zero ,cannot continue.
4. Waveguide for port nuber 1 is too short. The waveguide must be homogeneous for at least three mesh planes along propagation direction.
5. Too few conductors detected .Conductors might be short-circuited in port plane.
6. On port 2 multiple potential definitions of the same set are located on one conductor ,or a symmetry condition is incompatible with the potential definitions.
微波仿真論壇上看到的,除了第4個問題是因為端口處沒有加密到3個網(wǎng)格以外,其余的都還不知道怎么解決,拿來和大家一起探討下。
我用CST有些時間了,您遇到的問題主要都是波導(dǎo)端口的定義和端口處網(wǎng)格的定義上,答案如下。希望幫得上你。
1、這個提示并不是真正的本征模求解器的問題。CST的2008版以后的版本中對波導(dǎo)端口的求解精度進行了提高,每次進行仿真的時候,會自動對波導(dǎo)端口進行自適應(yīng)網(wǎng)格收斂性分析,并得到精確的結(jié)果。這里出現(xiàn)這樣的錯誤提示:主要是波導(dǎo)端口處的起始網(wǎng)格設(shè)置太粗,經(jīng)過了4次(缺省值)網(wǎng)格迭代后仍不能達到指定的1%(缺省值)的精度要求,所以計算停止了。解決方法:提高端口處的起始網(wǎng)格或者取消自適應(yīng)分析,更建議用前者。
2、要進行單端S參量計算,是要定義多芯端口的。CST叢書3中有多芯端口定義的詳細介紹,老兄可以買來看看。也不貴!
3、真不知道您是怎樣定義的波導(dǎo)端口,波導(dǎo)端口的傳播常數(shù)為0啊,這當(dāng)然不能繼續(xù)進行下去了。
4、還是波導(dǎo)端口的問題,波導(dǎo)端口的定義要求端口面處,傳播方向上至少要有3個網(wǎng)格才行的。
5、同樣,斷口處的網(wǎng)格太少,端口面上都短路了。
6、多芯端口定義的不對,這個錯誤說明您把多個電勢定義到同一根內(nèi)導(dǎo)體上了。這怎么行!建議你看看叢書3或者他們有本叢書9里面有個多層差分線的例子介紹的也挺好。
其實樓上下次遇到問題時,還可以把模型一并上傳。這樣幫你解答起來更有針對性地。:19bb
回答的很好啊,不錯,支持一下
:27bb
:27bb :27bb
CST的叢書3中有波導(dǎo)端口和多芯端口定義的詳細介紹。微波技術(shù)網(wǎng)上也有對多芯端口的簡單介紹啊。如附件就是從這里下載的。
http://imw.mwhrf.com/thread-7956-1-2.html
呵呵……
2樓好強大,推薦做CST版面小編,自愧不如,同時一并感謝
微網(wǎng)的熱心人就是多阿,二樓講解的很清楚哈:27bb
我翻譯的,呵呵~
:27bb :27bb :27bb :27bb
真的很不錯呀 希望繼續(xù)加油 繼續(xù)交流