CST STUDIO SUITE 2011 Service Pack 6 已發(fā)布
Service Pack 2011.06
General / Imports / Modeler
Fixed bug in DXF import for block items with negative rotation.
ADS import now considers expand operation of new ADS data format and upper/down attribute for thickening of planes.
Distributed Computing (DC)
Repaired issue of main controller if job is aborted while waiting for a free license.
Fixed merging of binary S-Parameter files for Linux frontend.
Improved robustness when sending result files from MainController to frontend.
CST MICROWAVE STUDIO - Transient Solver
Added support of NVIDIA Tesla M2090, M2070Q, M2075, and C2075 GPUs. New Feature!
CST MICROWAVE STUDIO - Frequency Domain (FD) Solvers
Changed mode type recognition for TEM/QTEM modes with high alpha in favour of the QTEM mode type.
Legacy mesh view engine now also displays the port meshes of the new port mode solver (which is active for curved mesh or shielded ports) with straight blue lines.
CST MICROWAVE STUDIO - Eigenmode Solver
The Eigenmode solver with tetrahedral mesh now records results for the parameter sweep watch frequency of mode.
Improved TET eigenmode solver accuracy.
Fixed problems of the linear equation system solver with a phase shift of the periodic boundary condition equal to 180 degree.
CST MICROWAVE STUDIO - Integral Equation Solver
Made farfield source reading more robust.
CST PARTICLE STUDIO Solvers
Secondary emission settings are stored properly now.
Tracking particle monitors record secondary electrons correctly.
CST CABLE STUDIO
Fixed cable modeling failure in case of co-simulation and model contains connector junctions.
Improved stability and performance of the cable mesher.
CST PCB STUDIO
Repaired cross-section mesh display.
SITD solver: Repaired generation of enable signals for active-low Ibis models.
Fixed that PCB overlap check sometimes detects untruly overlaps.
Repaired 2DTL mesh error: No transmission between overlapping nets.
No more overlap in peec meshing when layout check was ok.
Typ/best/worst setting is considered now in SITD solver dialog box.
Post Processing
Plotting of high resolution farfields made more robust.
SAR results are now recalculated if the underlying loss monitor has changed.
Repaired dB scaling in 2D ASCII export.
SAR result deletion removes now the logfile as well.
Phase normalization fixed for 1D Results from Asymptotic Solver.
Farfield main lobe analysis improved.
CST DESIGN STUDIO
Ensured that a project is extracted before it is assigned to a DS-Block.
Repaired vendor library problem with import of semiconductor models.
Fixed problem in vendor library file import due to duplicated line endings.
Fixed vendor library problem with parentheses in model definitions.
Avoid possible endless recursion, if calculation of DC conductance matrix fails.
Result Templates / VBA / Macros / External Data Access
Added a new COM method for closing a project. New Feature!
Added new VBA command GetPickedFaceAreaFromIndex. New Feature!
Fixed GetCurveLabelOfCurveIndex and GetCurveValue of Plot1D command.
VBA command introduced to load SAR results into the SAR object. New Feature!
這也太快了,剛才下載到SP5
等2011的補(bǔ)丁全了,我再裝。
太快了........
請(qǐng)問這個(gè)補(bǔ)丁是每個(gè)都要安裝,還是只要安裝最新補(bǔ)丁就可以了呢?謝謝!
補(bǔ)丁從哪可以下載呢?
德國(guó)的官網(wǎng)有下載嗎?
這也太快了,剛才下載到SP5